Product Detailed
Homecare respiration 1.Inspiration trigger for auto startup 2.Backlit LCD display for operation in dark 3.Alarm when accident

Homecare respiration

Product Feature: 

Item Number

D-CPAP 1

Main Feature

 

 

Continuous Positive Airway Pressure

 Reliable stability

1.Adopting the special designed air pump,provides users stable 2-20hPa therapy pressure.

2.Ramp capabilities allow a 0-60 minutes time period with adjustable ramp starting pressure.

3.Inspiration trigger for auto start-up

4.Automatic stop after put off mask

5.Alarm when accidental power-off

6.In time alert function when mask and/or tubing off-line

7.Automatic leakage and altitude compensation ensure the therapy accuracy anywhere.

8.Unique Delay-off feature protects RESmartTM from humidity hazard.

 Ergonomic design

1.Backlit LCD display for operation in dark

2.Lighted user buttons with lockup capability

3.Integrated designed InH2TM heated humidifier

4.Smart Heater automatic restarts after short term break.

5.Patented anti-countercurrent water tank

6.DC 24V powered and infrared controlled humidifier make user

Technical Specifications:

Device Size:

220 × 194 × 112 mm

313 × 194 × 112 mm (with InH2TM heated humidifier)

WG.:

2 kg

WorkTemperature:

5 to 40°C

Humidity:

≤80% Non-condensing

Atmospheric Pressure:

86 to 106 kPa

Standard Compliance:

IEC 60601-1 General Requirements for Safety of Medical Electrical Equipment

ISO 17510 Sleep Apnoea Breathing Therapy

AC Power Consumption:

100 – 240VAC, 50/60Hz

Type of Protection Against Electric Shock:

Class II Equipment

Degree of Protection Against Electric Shock:

Type BF Applied Part

Degree of Protection Against Ingress of Water:

IPX0 – Ordinary Equipment

Pressure Range:

2 to 20 hPa (in 0.5 hPa increments)

Pressure Stability:

2 to 20 hPa (±0.5 hPa)

Sound Pressure Level:

less then 30 dB

Maximum Flow:

more than 15 LPM

Pressure Display Accy.:

±0.5 hPa